Design optimization of a needle holder for in-space 3D printing

dc.contributor.authorEfstathiadis, Alexandrosen
dc.date.accessioned2018-04-28T09:36:47Z
dc.date.available2018-04-29T00:00:16Z
dc.date.issued2018-04-28
dc.identifier.urihttps://repository.ihu.edu.gr//xmlui/handle/11544/29045
dc.rightsDefault License
dc.subject3D printingen
dc.subjectSpaceen
dc.subjectOptimizationen
dc.subjectSurgicalen
dc.subjectNeedle holderen
dc.titleDesign optimization of a needle holder for in-space 3D printingen
heal.abstractThe current dissertation thesis documents the design optimization process of a surgical needle holder for in-space 3D printing. 3D printing can provide the means for an autonomous, crew-administered medical care system through an onboard digital catalog of 3D printable files that can be accessed on demand. As space missions become longer and more dangerous the need for on-board surgical capabilities becomes more urgent. The needle holder, used by a surgeon to hold the needle during suturing, is an integral part of a basic surgical kit. Commercially available needle holders were analysed and a digital model was produced in Solidworks 2016 after an existing stainless-steel instrument. A finite element analysis was run to analyse stress distribution and the model’s geometry was optimized accordingly for the FDM process. Areas like the fulcrum, jaws, handles and locking mechanism were thickened. To better inform the design process, six thermoplastic filaments were tested to determine their suitability for the needle holder fabrication. Two sets of specimens were printed from ABS, PLA, PETG and Nylon filaments and from composite ABS-Stainless Steel and Nylon-Fiber Glass materials. The first set was tested with their layers in a horizontal direction, as printed and the second with their layers on a vertical position, rotated 90o from printing direction. The materials demonstrated advantageous mechanical properties when the load force was vertical to the parts’ layering. Another observation was the brittle behavior of PLA and PLA-SS which could pose danger in case of a failure during a real medical emergency in zero-g conditions. Lastly, further simulation studies were conducted on the optimized digital model to examine its structural integrity when fabricated from the aforementioned materials. The vertical values calculated in the testing stage above were used. Inaccuracies of the Solidworks simulation utility in the analysis of 3D printed parts were taken into account. Nonetheless, the maximum exerted stress remained well below each material’s yield strength, making it safe to conclude that all the materials could be used for the fabrication of a functional needle holder. Slight preference could be given to Nylon-FG due to its high yield strength.en
heal.academicPublisherIHUen
heal.academicPublisherIDihuen_US
heal.accessfreeen_US
heal.advisorNameTzetzis, Dimitriosel
heal.committeeMemberNameTzetzis, Dimitriosen
heal.committeeMemberNameSymeonidou, Ioannael
heal.committeeMemberNameMichailidis, Nikolaosel
heal.keywordURI.LCSHThree-dimensional printing
heal.keywordURI.LCSHMedical instruments and apparatus--Design and construction--Case studies
heal.keywordURI.LCSHBiomedical materials--Design
heal.keywordURI.LCSHBiomedical materials--Technological innovations
heal.languageenen_US
heal.licensehttp://creativecommons.org/licenses/by-nc/4.0en_US
heal.numberOfPages88en_US
heal.publicationDate2018-04-05
heal.recordProviderSchool of Economics, Business Administration and Legal Studies, MSc in Strategic Product Designen_US
heal.typemasterThesisen_US

Αρχεία

Πρωτότυπος φάκελος/πακέτο

Τώρα δείχνει 1 - 1 από 1
Φόρτωση...
Μικρογραφία εικόνας
Ονομα:
1106150010.pdf
Μέγεθος:
5.04 MB
Μορφότυπο:
Adobe Portable Document Format
Περιγραφή:

Φάκελος/Πακέτο αδειών

Τώρα δείχνει 1 - 1 από 1
Δεν υπάρχει διαθέσιμη μικρογραφία
Ονομα:
license.txt
Μέγεθος:
2.58 KB
Μορφότυπο:
Item-specific license agreed upon to submission
Περιγραφή:

Συλλογές